Yuasa Yucel Y9-12
Design life : 3 - 5 Year design life when used in standby applications.
Warranty: 1 Year
Commonly used in UPS Systems ,Alarm Systems, Emergency Lighting, Ride on Toys, Torches and other electrical systems
Price: £20.85
Price With Tax: £25.02
|
SPECIFICATIONS |
||
|
Nominal voltage |
12 |
V |
|
20-hr rate Capacity to 1.75VPC at 20°C |
9 |
Ah |
|
10-hr rate Capacity to 1.75VPC at 20°C |
7.87 |
Ah |
|
DIMENSIONS |
||
|
Length |
151 (±1) |
mm |
|
Width |
65 (±1) |
mm |
|
Height |
94.5 (±1) |
mm |
|
(height over terminals) |
100 (±2) |
mm |
|
Mass (typical) |
2.75 |
kg |
|
TERMINAL TYPE |
||
|
FASTON (Quickfit / release) |
4.75 |
mm |
|
OPERATING TEMPERATURE RANGE |
||
|
Storage |
-20°C to +60°C |
|
|
Charge |
-15°C to +50°C |
|
|
Discharge |
-20°C to +60°C |
|
|
STORAGE |
||
|
Capacity loss per month at 20°C (approx) |
3 |
% |
|
CASE MATERIAL |
||
|
Standard Option |
ABS (UL.94:HB) |
|
|
Flame retardant option (FR) |
ABS (UL94:V0) |
|
|
CHARGE VOLTAGE |
||
|
Float charge voltage at 20°C |
13.65 (±1%) |
V |
|
2.275 (±1%) |
V/cell |
|
|
Float Charge voltage temperature correction factor (for variations from the standard 20°C) |
-3 |
mV/cell/°C |
|
Cyclic (or Boost) charge at 20°C |
14.5 (±3%) |
V |
|
2.42 (±3%) |
V/cell |
|
|
Cyclic Charge voltage temperature correction factor (for variations from the standard 20°C) |
-4 |
mV/cell/°C |
|
CHARGE CURRENT |
||
|
Float charge current limit |
No limit |
A |
|
Cyclic (or Boost) charge current limit |
2.25 |
A |
|
MAXIMUM DISCHARGE CURRENT |
||
|
1 minute |
48 |
A |
|
SHORT-CIRCUIT CURRENT & INTERNAL RESISTANCE |
||
|
(according to EN IEC 60896-21) |
||
|
Internal resistance |
N/A |
m! |
|
Short-Circuit current |
N/A |
A |
|
IMPEDANCE |
||
|
Measured at 1 kHz |
18 |
m! |
|
PERFORMANCE & CHARACTERISTICS |
||
|
Refer to the technical manual |
YUCEL |
|
|
DESIGN LIFE |
||
|
EUROBAT Classification: Standard Commercial |
3 to 5 |
years |
|
Yuasa design life @ 20°C |
up to 5 |
years |
|
SAFETY |
||
|
Installation Can be installed and operated in any orientation except permanently inverted |
||
|
Handles Batteries must not be suspended by their handles (where fitted) |
||
|
Vent valves Each cell is fitted with a low pressure release valve to allow gasses to escape and then reseal. |
||
|
Gas Release VRLA Batteries release hydrogen gas which can form explosive mixtures in air. Do not place inside a sealed container |
||
|
Recycling YUASA's VRLA batteries must be recycled at the end of life in accordance with local and national laws and regulations |
||